Chapter 4 Generally Applicable Development Standards
Part 7 Development on Steep Slopes
4.7.1 Purpose & Intent
The purpose of this Part is to guide development in steeply
sloped or unstable hillside areas consistent with Cornerstone 2020
Comprehensive Plan guidelines, to protect natural areas and features and to
locate development, where possible, in areas that do not have severe
environmental limitations. This section intends to regulate hillside
development in order to protect life and property from hazards due to slope,
unstable soils, earth movement and other geologic and hydrologic hazards. More
specifically, these regulations are intended to:
- Maintain property values and avoid property damage due to
development of steep slopes and unstable soils;
- Incorporate current design, landscape architecture, architecture and
civil engineering practices to preserve, enhance, and/or promote the stability
and environmental quality of hillside areas;
- Preserve or enhance the beauty of the landscape by encouraging the
maximum retention of natural topographic features including slopes, ridge
lines, vistas, and natural plant communities;
- Promote a safe means of ingress and egress for vehicular and
pedestrian traffic to and within hillside areas while at the same time
minimizing the scarring effects of hillside street construction;
- Encourage imaginative and innovative building techniques to create
buildings suited to natural hillside surroundings; and
- Enhance neighborhood character and community identity associated
with the Countys hillsides.
From Definitions (Chapter 1 Part 2):
Land Disturbing
Activity All construction, demolition, reconstruction modification,
extension, or expansion of structures or parking areas, placement of fill,
dumping, storage of earthen materials, excavation, land clearing,
clear-cutting, tree and vegetation removal, grading, grubbing or any similar
activity or combination thereof that changes the natural cover or topography
creating the potential for erosion and contribution to sediment. |
4.7.2 Applicability & Exemptions
- Applicability
This Part shall apply to all land disturbing
activity, including new development and subdivision, proposed on:
- Properties that contain slopes of 20% or greater (steep
slopes), or
- Properties that contain soils rated as unstable on
Core Graphic 5.
- Land Disturbing Activity
Land disturbing activity includes
the following:
- Clearing of more than 5,000 square feet of forested area for
development;
- Grading, excavation, construction of foundations, footings or
retaining walls, or alteration of the ground surface, except for activities
defined as agricultural operations in KRS 224.71-100 through 140;
- The installation of utilities, including but not limited to
water, sewer, natural gas, electric, telephone and cable.
- Exemptions
This Part shall not apply to the development
activities listed in 4.6.1.B.
4.7.3 Development on Steep Slopes
- Measurement of Steep Slopes
The restrictions on development
on sloped areas in this Part refer to existing (pre-development) site
conditions. Slopes shall be determined by dividing the horizontal run of the
slope into the vertical rise of the same slope and converting the result into a
percentage value.
Steepness of slope shall be measured from the points
with the highest and lowest elevation between slope breaks. The Planning
Director in consultation with NRCS representatives shall make the final
determination of what constitutes a slope break.
4.7.4 Land Disturbing Activity on Unstable Soils.
- Land disturbing activity on unstable soils (as depicted on Core
Graphic 5) is permitted only in accordance with the Comprehensive Plan and in
keeping with the following:
- The Planning Commission determines the proposed construction
cannot be accommodated on a portion of the site that does not contain unstable
soils; and,
- The application for the land disturbing activity includes a
geotechnical survey report, prepared in accordance with best practices. For
land disturbing activity in conjunction with a plan review (preliminary
subdivision plan, development plan, conditional use plan, etc.) required by
this code, a geotechnical report shall be submitted with the application for
the required review. Such survey will ordinarily include information obtained
by drilling, locating of bedrock and testing of soils for shear strength. The
report shall be prepared by a licensed and Kentucky-registered professional
engineer practicing in accordance with KRS 322 and whose area of expertise
includes geotechnical engineering. In order for the proposed construction to be
approved, the report must:
- conclude the proposed disturbance and/or construction can be
carried out in a manner that will minimize impact on the slope and will not
adversely impact foundation stability on the subject property and surrounding
properties; and,
- conclude that stable foundations can be constructed on the
site and identify the mitigation measures and construction practices, including
construction supervision, necessary to assure the stability of buildings and
foundations to be constructed on the site; and,
- include erosion and sediment control measures necessary to
assure compliance with the Jefferson County Erosion and Sediment Control
Ordinance; and,
- The applicant provides a plan, acceptable to the Commission,
that specifies how the mitigation measures and construction practices including
construction supervision, necessary to assure the stability of buildings and
foundations to be constructed on the site as recommended in the geotechnical
report will be implemented.
- Prior to requesting a full building permit, the applicant shall
provide certification from a professional engineer having the qualifications
described in paragraph 2, above, that site preparation and foundation
construction were carried out in accordance with the approved mitigation
measures and construction practices.
- Prior to requesting a certificate of occupancy for any structure
on the site, the applicant shall provide certification from a geotechnical
soils engineer certifying that land disturbance and construction were carried
out in accordance with the mitigation measures and construction practices,
including inspections, set forth in the geotechnical report.
- Prior to site disturbance, the applicant shall submit a bond of
sufficient amount to cover the cost of site stabilization.
4.7.5 Land Disturbing Activity on Slopes Greater Than
20%.
- Land disturbing activity on slopes greater than 20% is permitted on
lots existing prior to the effective date of this regulation and on lots
created by minor plats submitted for review after the effective date of this
regulation only if the activity is in keeping with the Comprehensive Plan and
the proposed activity complies with the following standards:
- The Planning Director finds that the design and configuration of
the development results in the minimum disturbance of slopes greater than 20%
necessary to accommodate the proposed use of the site; and,
- Compatible on-site utilities (electric, phone, cable) are placed
in a common trench; and,
- Shared access driveways serving single family residences are
used when this technique reduces pavement and grading of steep areas.
- Land disturbing activities on slopes greater than 20% is permitted
on lots created by major subdivision after the effective date of this
regulation only if the activity is in keeping with the Comprehensive Plan and
the proposed activity complies with the following standards:
- The Commission finds that the design and configuration of the
development results in the minimum disturbance of slopes greater than 20%
necessary to accommodate the proposed use of the site; and,
- Compatible on-site utilities (electric, phone, cable) are placed
in a common trench; and,
- Land disturbing activities on slopes greater than 20% and less
than 30% shall be required to prepare a geotechnical survey report if the staff
of the USDA Natural Resources Conservation Service determines such a study is
warranted, given the sites soil and geologic characteristics. A
geotechnical report shall be submitted for land disturbing activities on slopes
greater than 30%. The geotechnical survey report shall be submitted with the
application for land disturbing activities and with the application for a plan
review (preliminary subdivision plan, development plan, conditional use plan,
etc.) required by this code and shall be prepared in accordance with best
practices. Such survey will ordinarily include information obtained by
drilling, locating of bedrock and testing of soils for shear strength. The
report shall be prepared by a licensed and Kentucky-registered professional
engineer practicing in accordance with KRS 322 and whose area of expertise
includes geotechnical engineering. The report shall include mitigation measures
as needed to ensure stability and minimize environmental impact during site
preparation and construction phases of the regulated activity. In addition, the
report shall include erosion and sediment control measures necessary to assure
compliance with the Jefferson County Erosion and Sediment Control Ordinance.
The Planning Commission may approve the activity if the report opines and
demonstrates that:
- The slopes ground surface and subsurface are not
unstable;
- Development of the slope and associated mitigation measures
will not increase the degree of risk of slope instability both on-site and on
adjacent lands; and,
- If a geotechnical report is required, the applicant provides
a plan, acceptable to the Commission, that specifies how the mitigation
measures and construction practices, including construction supervision,
necessary to assure the stability of buildings and foundations to be
constructed on the site as recommended in the geotechnical report will be
implemented.
4.7.6 Independent Review of Geotechnical Survey
Report
The Planning Commission may, on recommendation of the
Natural Resource
Conservation Service or MSD or the Planning Director,
require an independent review of the submitted geotechnical survey report. Such
review shall be conducted by a licensed and Kentucky-registered professional
engineer practicing in accordance with KRS 322 and whose area of expertise
includes geotechnical engineering. The reasonable cost of such review shall be
borne by the applicant.
4.7.7 Development Potential Transfer Allowed
-
| NOTE: Although lot sizes are reduced, setbacks are not reduced
for density transfer lots. Consistent appearance throughout the subdivision is
intended. |
Major subdivision development proposals submitted after the
effective date of this regulation and which permanently preserve areas of the
site with slopes greater than 20% may transfer the development potential
(building sites or floor area) of the permanently preserved area to the
remainder of the site subject to the following limitations:
- The subdivision is not being developed under the Alternative
Development Incentives of the Land Development Code; and,
- Areas to be permanently preserved are preserved in a manner
acceptable to the Commission (e.g., conservation easement, common open space,
etc.); and,
- The area of the site to which development potential is being
transferred is at least as large as the area from which development potential
is being transferred (for example; if an applicant wishes to transfer
development potential from 3 acres, the portion of the site to which
development is shifted must be at least 3 acres); a
- All lots in the proposed development meet the minimum
alternative development incentive lot size of the applicable Form District;
and,
- All lots in the proposed development meet the height, yard and
setback requirements of the applicable Form District.
- The maximum development potential allowable for transfer shall be
determined by one of the following methods:
- One half of the theoretical development potential based on the
number of acres preserved and the existing zoning of the area to be preserved
(for example; if 3 acres of an R-4 site is proposed for protection, then 7
building sites could be transferred to other portions of the same property -
3ac x 4.84 units/acre / 2 = 7.26 units); or,
- The realistic development potential determined by an engineered
development plan including a preliminary geotechnical feasibility study and
meeting all other requirements of the Land Development Code.