Chapter 4 Generally Applicable Development Standards
Appendix 4G Floodplain Management Page 2 of 3
- FLOOD HAZARD REDUCTION PROVISIONS
- Local Regulatory Conveyance Zone
- No development, shall occur in the local regulatory
conveyance zone except as approved in a permit issued by the administering
agency and are
- Detention, retention, or other stormwater, flood
control, or water quality facilities which are beneficial to the stream
corridor and riparian environment or
- Uses consisting of open space which are in conformance
with the Zoning Regulations of Louisville and Jefferson County and are
associated with bona fide agriculture, silviculture, recreation, parking, and
storage that whether in place or dislodged would not contribute to an increase
in the local regulatory base flood elevation or
- Necessary for navigation and waterborne freight handling
or
- Necessary for transportation or utility crossings
or
- Structures related to those in (ii) or (iii) above so
long as the structures are designed, constructed and sited so as to offer the
minimum obstruction to flows during a local regulatory flood or
- Functionally dependent facilities which considered alone
or with development up and down stream and across the stream are not likely to
contribute to an increase in the local regulatory base flood elevation.
- No permit shall be required for
- Customary and incidental routine grounds maintenance,
landscaping, and home gardening which does not require zoning approval, a
zoning variance or a building permit and which does not affect stormwater
drainage entering or leaving any public right-of-way or
- Emergency repairs of a temporary nature made on public
or private property which are necessary for the preservation of life, health or
property, and which are made under such circumstances where it would be
impossible or impracticable to obtain a floodplain permit or
- Temporary excavation for the purpose of repairing or
maintaining any public street, public utility facility or any service lines
related thereto.
- No person shall store materials, which are flammable,
explosive, reactive, toxic, corrosive or because of their buoyancy or other
properties may be injurious to human, animal or plant life in the local
regulatory conveyance zone.
- Streams
For "solid blue line streams"
- Notwithstanding anything in this Part C to the contrary, no
relocation, channelization, or stripping of the stream, stream banks, or
channel shall occur except for public projects such as road crossings,
installation of utilities, flood control measures, drainage and outfall pipes,
detention basins, retention basins or water impoundments and for projects with
benefit to the public in preventing flooding provided such projects are
essential to protect the health, safety, and welfare of local residents, such
projects are the only alternative which is viable, and all exceptions are
approved by the administering agency, the Louisville and Jefferson County
Planning Commission, the Kentucky Division of Water, and if applicable, the U.
S. Army Corps of Engineers.
- A natural vegetation buffer strip shall be preserved at
least twenty-five feet on each side of the stream bank as defined by the
hydraulic model of the channel. In areas not already disturbed by urban,
suburban, or agricultural land uses prior to the effective date of this
ordinance, existing over story and under story trees shall be preserved and
shrubs and ground covers shall be maintained along the stream bank sufficient
to naturally maintain the integrity of the channel.
- When removal of vegetation within the buffer strip specified
in (ii) above is necessary for the location and construction of a public
project or project with benefit to the public in preventing flooding described
in 2 (a) above, native vegetation which thrives in riparian environments shall
be replanted prior to completion of construction sufficient to naturally
maintain the integrity of the channel.
- Local Regulatory Floodplain
- Floodplain Permit.
No person shall begin development
in the local regulatory floodplain unless and until a floodplain permit has
been issued by the administering agency.
- Required Issuance.
The administering agency shall
issue a floodplain permit for
- Development, not including critical facilities, for use
as a residence
- consisting of new construction or substantial
improvement where the lowest floor including the basement if any is elevated at
least one foot above the local regulatory base flood elevation or
- consisting of existing development other than
substantial improvement which
- replaces or repairs the pre-existing condition
of development or constructs additions or remodeling which do not constitute
substantial improvement without diminishing the storage capacity or the amount
and velocity of the transmission of flood waters through the local regulatory
floodplain from what was present prior to the replacement or repair or
- floodproofs the existing development below the
local regulatory base flood elevation plus one foot so that those areas
including all mechanical and utility equipment below the required elevation are
watertight with walls substantially impermeable to the passage of water and
structural components are used which have the capability to resist hydrostatic
and hydrodynamic loads and the effects of buoyancy which capabilities shall be
certified by a registered professional engineer or architect and provided to
the administering agency and
- floodproofs any addition or elevates it no less
than one foot above the local regulatory base flood elevation
- consisting of emplacing a manufactured home
- in an existing manufactured home park which
- elevates the lowest floor of the
manufactured home at least one foot above the local regulatory base flood
elevation or
- supports the manufactured home chassis by
reinforced piers or other foundation elements of at least an equivalent
strength of no less than 36 inches in height above grade,
- and in either (a) or (b) above, firmly
anchors the manufactured home to the securely anchored foundation so as to
resist flotation, collapse and lateral movement.
- in a newly constructed or substantially improved
or expanded manufactured home park or the new construction or substantial
improvement or expansion of such a manufactured home park which
- emplaces the manufactured home on a building
pad which is raised no less than one foot above the local regulatory base flood
elevation and
- firmly anchors the manufactured home to the
securely anchored foundation so as to resist flotation, collapse and lateral
movement.
- In an existing new or expanded manufactured home
park where the owner notifies all owners or lessees of manufactured homes to be
located in the manufactured home park of the requirements of this section
C3(b)(I)(C) and insures their compliance with those requirements.
- On any lot created after the effective date of this
ordinance, no new construction shall occur unless access to the lot is
available from a road which is at or above the local regulatory base flood
elevation.
- Development, other than a critical facility, for all
other uses
- where the lowest floor including basement if any and
all mechanical and utility equipment are elevated at least one foot above the
local regulatory base flood elevation or
- where development consists of new construction or
substantial improvement where the portion of the new construction or
substantial improvement below the local regulatory base flood elevation plus
one foot is floodproofed so that those areas including all mechanical and
utility equipment below the required elevation are watertight with walls
substantially impermeable to the passage of water and structural components are
used which have the capability to resist hydrostatic and hydrodynamic loads and
the effects of buoyancy which capabilities shall be certified by a registered
professional engineer or architect and provided to the administering
agency.
- existing development not consisting of substantial
improvement which
- replaces or repairs the pre-existing condition
of development without diminishing the storage capacity or the amount and
velocity of the transmission of flood waters through the local regulatory
floodplain from what was present prior to the replacement or repair or
- floodproofs the existing development as repaired
or replaced in accordance with the standard provided in section (ii)(B) above,
and
- floodproofs any addition or elevates it no less
than one foot above the local regulatory base flood elevation
- Development for Critical Facilities.
- a critical facility consisting of substantial
improvement so long as it meets the other requirements of this section (ii)(A)
and (B) provided that the lowest floor including the basement if any is
elevated at least one foot above the local regulatory base flood elevation and
it has at least one access road capable of supporting a vehicle weighing 12,500
pounds which road is connected to land outside the local regulatory floodplain
and the top of which road is no lower than one foot above the local regulatory
base flood elevation.
- a critical facility not consisting of new
construction or substantial improvement which
- replaces or repairs the pre-existing condition
of development without diminishing the storage capacity or the amount and
velocity of the transmission of flood waters through the local regulatory
floodplain from what was present prior to the replacement or repair or
- floodproofs the existing development as repaired
or replaced in accordance with the standard provided in section (ii)(B) above,
and
- floodproofs any addition or elevates it no less
than one foot above the local regulatory base flood elevation.
- Permissive Issuance.
The administering agency may
issue a floodplain permit if the proposed development is consistent with the
purposes of this ordinance and the factors listed below have been considered
and either avoided or mitigated:
- the danger to life and property presented by a local
regulatory flood;
- the susceptibility of the proposed facility and its
contents to damage from a local regulatory flood and the effect of such damage
on the individual owner;
- the danger that in a local regulatory flood materials
may be swept onto other lands to the injury of others;
- the safety of access to the property in times of a local
regulatory flood for ordinary and emergency vehicles;
- the costs and feasibility of providing governmental
services during and after a local regulatory flood, including fire protection,
emergency medical services, police protection, maintenance and repair of
streets and bridges and of providing safely operating public utilities and
facilities such as sewer, gas, electrical and water systems;
- the expected heights, velocity, duration, rate of rise
and sediment transport of the waters from a local regulatory flood expected at
the site.
- General Provisions.
- For a floodplain permit issued under either (b) or (c)
above, any Part of the development which is elevated above the adjacent grade
- If solid foundation perimeter walls are to be used
to elevate the structure above the local regulatory base flood elevation,
- There shall be provided openings sufficient to
facilitate the unimpeded movement of flood waters and equalize hydrostatic
flood forces on exterior walls which capabilities shall be certified to the
administering agency by a professional engineer or architect or which designs
shall provide openings in each wall having a total net area of not less than
one square inch for every square foot of enclosed area subject to flooding, and
the bottom of all openings shall be no higher than one foot above grade; and
openings equipped with screens, louvers, valves or other coverings or devices
shall permit the automatic flow of flood waters in both directions, an
- All space within the area created by the solid
perimeter walls shall be designated undevelopable space with a restriction
recorded with the deed of such designation evidence of which recorded
restriction shall be provided to the administering agency before approval of
the floodplain permit, and
- The interior portion of the area shall not be
partitioned or finished into separate rooms.
- If piers, posts or columns are to be used to achieve
the elevation, the area encompassed by the piers, posts or columns shall not be
designated living space, but shall be designated undevelopable space and shall
be so restricted on the deed to the property filed in the Office of the Clerk
of Jefferson County, the pile or column foundation and structure attached
thereto shall be anchored to resist flotation, collapse and lateral movement
due to effects of water load which values shall be those associated with a
local regulatory base flood, and the design shall be certified by a registered
engineer as meeting accepted standards of practice for such structures.
Breakaway walls shall be non-supporting and designed to collapse without
causing collapse or displacement or other structural damage of the elevated
building.
- For a floodplain permit issued under Section C3(b) or
(c) above, any development which displaces any storage capacity for floodwaters
in the local regulatory floodplain shall provide floodplain storage
compensation.
- No floodplain permit shall be issued under Section C3(b)
or (c) above for development constituting substantial improvement or repairs or
replacement on existing development to be used for storage of materials which
are flammable, explosive, reactive, toxic, corrosive or because of their
buoyancy or other properties may be injurious to human, animal or plant life
unless plans have been presented by the permit applicant acceptable to the
administering agency to keep the materials secure, to anchor the containers so
they do not float away and to prevent spillage or leakage in the event of
flooding and such plans have been attached to the floodplain permit as
conditions, provided that occupants of properties zoned for residential use may
store de minimis quantities of these materials sufficient for the occupants'
personal use on the property.
- Except for police stations and fire stations, no new
construction of critical facilities shall occur in the local regulatory
floodplain and no elevation shall be permitted for new construction of critical
facilities (except for police stations and fire stations) to raise them above
the local regulatory base flood elevation.
- Certificate of Elevation.
- No person shall allow or permit construction to proceed
beyond the lowest floor until a registered land surveyor or registered engineer
has submitted to the administering agency a certificate of elevation on a form
approved by FEMA stating the elevation of the lowest floor and that it conforms
to the requirements of the floodplain permit regarding the elevation of the
lowest floor.
- No person shall use or occupy a structure which by terms
of the floodplain permit is to be floodproofed until a registered engineer or
architect licensed in the Commonwealth has completed and filed with the
administering agency a certificate of floodproofing on a form approved by
FEMA.
- Expiration of Floodplain Permit.
If the holder of a
floodplain permit has not commenced construction within one (1) year from the
date of its issuance by the administering agency, the floodplain permit shall
expire and no development shall be permitted on the subject property unless and
until a new floodplain permit is issued, provided that the term of an approved
floodplain permit may be extended if the assumptions under which the permit was
issued remain valid and the extension is approved in writing by the
administering agency before the floodplain permit expires with no more than two
one-year extensions to be approved. Demolition, site clearing, and site
preparation do not constitute commencing construction for the purpose of this
section.
- Conformance with Floodplain Permit.
No person who
has obtained a floodplain permit shall construct development except in
accordance with its terms.
- Nonconforming Use.
An existing development which was
lawful on the effective date of this ordinance but which is not in conformity
with the provisions of this ordinance may be continued so long as
- the existing development is not expanded or enlarged
except in conformity with the provisions of this ordinance and
- any alteration, addition or repair of the existing
development, either which was the consequence of damage from any source equal
to fifty (50%) percent or more of the value of the existing development
immediately before the damage occurred or which involves a cost in excess of
fifty (50%) percent of the market value of such existing development and in
either case is made only in conformity with the provisions of this
ordinance.
- Consent to Public Construction
Notwithstanding any
provision in this ordinance to the contrary, no structure or improvement shall
be constructed nor change in topography imposed nor shall any other development
be carried out by any public entity without specific consent's having been
granted by the property owner or its designee or agent or by a Court in a legal
proceeding separate and apart from this ordinance nor shall any use be made of
the property by any public entity without specific consent for such use having
been granted by the property owner or its designee or agent or by a Court in a
separate legal proceeding. This section applies only to this ordinance and the
activities and facilities provided for by the terms of this ordinance.