Chapter 5 Form District Regulations Part 5
Non-Residential/Mixed Use Site Design Standards
5.5.1 Traditional Form District Design Standards
- General Site Design Standards (Downtown Form District excluded)
- Building Location and Orientation
- Principal building entrances shall face the primary street
serving the development or shall be oriented toward a focal point such as a
landscaped public square, plaza or similar formal public open space. All
structures that are located along the primary street serving the development
shall also have doors or windows facing the primary street (see b. Below for
lots with more than one street frontage). Principal buildings shall be parallel
to the primary street. If the prevalent (more than 50%) orientation of
buildings on the block is at an angle to the street, the new buildings
orientation shall be the same as other buildings. The walls of buildings on
corners should be parallel to the streets.
- Retail and office uses within buildings facing two or more
streets shall have at least one customer entrance facing the primary street and
one customer entrance facing the second street or instead of two entrances, a
corner entrance.
- Corner Lots. On corner lots, the building shall be constructed
at the right-of-way line along both of the streets. Lots with more than one
street corner shall build to the corner that contains frontage on the primary
street. Additional buildings on the multi-corner lot shall be built to the
secondary corner. The intersection of a street with an alley shall not be
considered a street corner.
Exceptions: 1) if a principal building or
tenant entrance is at the corner, the angular façade containing the
entrance may be recessed a maximum of 15 feet from the intersection of the two
right-of-ways lines; 2) if the sidewalk abutting the corner property is less
than the sidewalk width required by the applicable form district, the building
may set back to permit the construction of the required sidewalk.
- Parking Location:
- Parking Location and Design. Parking lots shall not be
permitted in front of buildings and shall be located and designed to reduce or
eliminate visual or operational impacts to surrounding properties. Parking lots
at or within the maximum setback shall not be closer to the right-of-way line
than the principal structure(s). Side parking that exceeds 40 percent of the
total linear lot frontage adjacent to right-of-way shall provide a minimum 3
foot masonry, stone or concrete wall that makes reference to a similar design
within the surrounding area extending from the principal structure across the
front of the parking area. Surface parking lots with no principal structure(s)
shall provide the 3 foot wall as described above. EXCEPTION: Industrial uses
are exempt from the 3 foot wall requirement as described above.
| Connections from public right-of-way through parking
areas shall be provided in accordance with Chapter 5, Part 9 Transit and
Connections. |
- Parking Lot Design. Where an alley exists, vehicular and
parking access to the site shall include alley access.
- Parking decks. Surface or structure parking shall not be
located between the public right-of-way and building facades. Parking decks
that are visible from a public street shall be consistent with the design and
materials of the principal structure.
- Connections between Parking Lots Vehicular and
pedestrian connections between parking lots of abutting developments are
required in order to reduce traffic on main thoroughfares and to allow
customers to visit multiple establishments without moving their vehicles.
(Note: Not required for TWFD)
- Loading and Refuse Collection Areas:
- Loading Areas. Off-street loading and refuse collection
areas shall be located and screened so as not to be visible from adjacent
public streets and from residential uses.
- Front loading docks (on the primary facade) are not
permitted. On-street loading areas are discouraged unless rear or side loading
areas are not possible due to site constraints.
- All attached and detached canopies for gas stations, banks and
other similar uses shall not be between the associated principal structure and
the public street. There shall be no drive lanes between the principal
structure(s) located between the maximum setback and the public street.
Detached and attached canopies for fueling stations and banks shall not be
closer to the public street than the structures located between the maximum
setback and the public street.
- Secondary Structures. Separate, secondary structures (includes
but not limited to, freestanding canopies over gas pumps, cashier booths, bank
drive-throughs and car washes) shall have the same architectural details,
design elements, building materials, and roof design as the primary
structures.
- Downtown Form District
- Parking and loading standards have been established for the
Downtown Form District to manage the supply of off-street parking to improve
mobility, promote the use of alternative modes of transportation, support
existing and new economic development, maintain air quality, and enhance the
urban form of the District. Parking shall be furnished in conformance with
Chapter 9 Part 1 (Motor Vehicle Parking and Loading Standards), except as
provided in this subsection.
| Parking should have the same qualities and characteristics
as any other downtown development, relating strongly to nearby buildings and
should be designed to promote comfort and safety for pedestrians on the street
and the sidewalk. |
- Surface Parking
- Surface parking lots shall be prohibited along the Main
Street and Fourth Street rights-of-way.
- Surface parking shall be located completely behind all
principal structures and shall be accessed at the rear of the property via an
alley. When alley access is not possible, the Director of Works shall determine
access.
- Landscape screening and tree canopy requirements for
surface parking areas shall conform to Chapter 10 of these regulations with the
exception that tree canopy requirements shall be provided for any new surface
parking area or any existing surface parking area when 25% or more of the lot
is resurfaced.
- Surface parking lighting shall conform to Chapter 4 Part
1, Lighting Standards.
- Parking Structures
- Parking structures shall adhere to all building location
and design standards set forth in Section 5.2.1 and Section 5.6.2 of these
regulations.
- Ramped floors shall not be visible from the street.
- At least 50 percent of the first floor street facade
must be developed for Retail or Office uses. Areas designed to accommodate
these uses may be developed at the time of construction, or may be designed for
later conversion to such uses.
- Garage entries and exits for both pedestrians and
vehicles shall be clearly marked by materials, lighting, signage, etc., to
ensure pedestrian safety.
| NOTE: The parking lot design standards apply to
lots constructed after the effective date of the LDC. Retrofitting of existing
facilities is not required. |
5.5.2 Suburban Form District Design Standards
- Building Location and Orientation
- Principal buildings and building entrances on a site shall have
entrances and glazing, display windows or windows affording views into the
business which face the abutting public street serving the development In the
alternative, principal buildings and entrances shall be oriented toward a focal
point. Structures located at a street corner may have a single entrance,
located at the corner of the building. Buildings with frontage on two streets
shall have consistent building design and materials on each façade.
Internally oriented structures closest to the public street(s) serving the
development shall also have doors or windows facing the street.
- Parking and Loading Design and Location
- Parking Lot Configuration
- Connections between Parking Lots Vehicular and
pedestrian connections between parking lots of abutting developments are
required in order to reduce traffic on main thoroughfares and to allow
customers to visit multiple establishments without moving their vehicles.
(Note: Not required for SWFD and CFD)
- Loading Areas Off-street loading and refuse collection
areas shall be located and screened so as not to be visible from adjacent
public streets and residential uses. Screening may be accomplished through use
of a fence with landscaping that at maturity will equal the height of the
fence, or a wall constructed of the same building materials as the principal
structure.
- Suburban Form District Specific Design Standards
- Suburban Workplace Form District
- Loading Areas Loading areas shall not be located in
the required front or street side setback.
- Campus Form District
- Parking Lot Location Parking shall not be located in
the required front, side or rear setbacks. No more than 50% of the required
parking spaces shall be located between a building and the abutting primary
street or private access easement that provides the principal means of access
to parcels in major subdivisions.
- Loading docks are not permitted on primary façades.
5.5.3 Mixed Use Development (not applicable within DFD
and NFD)
- Up to 25 percent of any non-residential development site may be
allocated to residential development without any corresponding decrease in the
maximum allowable square footage or intensity of non-residential uses allowed
by the underlying zoning district. Calculation of permissible residential
density shall be based on the net site area, regardless of the amount of
non-residential floor area constructed on the site. Upper story office and
residential uses shall be excluded from the calculation of a sites
permissible floor area in the following circumstances.
- Up to three stories (not to exceed maximum height within form
district) of residential use, when located above first floor office or
commercial use.
- Up to two stories (not to exceed maximum height of form
district) of office use, when located above office or commercial use.
5.5.4 Form District Specific Compatibility
Standards
- Town Center Form District Specific Compatibility Standards
- Building design may be used to ensure a compatible transition
between uses (e.g., location of principal structures, garages, parking areas,
alleys, or similar features may provide a buffer between residences and
adjacent areas).
- Perimeter masonry walls or a combination of masonry wall and
landscaping between residential uses and more intense uses may be substituted
for the required property perimeter buffer yard to promote a more compact
pattern of development.
- Suburban Workplace Form District Compatibility Standards
- Industrial uses, including structures, loading and truck parking
areas, and outdoor storage located within 200 feet of and having a common lot
line with residentially used or zoned parcels shall include a 50 foot landscape
buffer area with a 6 foot berm and canopy trees as required by Chapter 10, Part
2.
- Traditional Marketplace Corridor Form District Compatibility
Standards
- Fences or walls (minimum 80% opacity) may be substituted for the
required property perimeter buffer yard to promote a more compact pattern of
development. Tree planting as specified in Chapter 10, Part 2 is still required
for sites using fences or walls in lieu of a perimeter buffer yard. Such fences
or walls shall be six feet in height and constructed of durable materials
compatible with the visual character of the surrounding area. The Planning
Director shall determine acceptable wall and fence materials.
- Development within the TMCFD shall be designed to incorporate
enhanced protection and noise reduction measures next to residential uses.
Examples of measures to enhance compatibility with
residential uses include, but are not limited to:
- Location of obtrusive uses such as truck access and
loading areas and outdoor trash areas away from residential uses
- Use of a rear alley to separate rear parking lots
and adjacent residential lots
- Screening of mechanical equipment
- Enhanced lighting controls
Controls on the location of outdoor use areas (e.g.,
vending areas, garden display areas, etc.) |
- Traditional Neighborhood Form District Compatibility Standards
- Non-residential and mixed-use development shall be designed to
incorporate enhanced buffer protection and noise reduction measures next to
residential uses. Examples of additional buffers and noise reduction measures
include:
- Location of obtrusive uses such as truck access, loading and
outdoor trash areas away from residential uses.
- Location of outdoor use areas and vending areas away from
residential uses.
5.5.5 Accessory Structure Standards
- Standards for Accessory Structures (other than accessory structures
to single-family residential development)
- Accessory structures (e.g. dumpsters, storage buildings, HVAC
equipment, fast food ordering stations/menu boards and similar uses) shall not
be constructed or permitted within any required setback/yard. These structures
shall be subordinate in size to the principal structure, shall not be visible
from the public street, and shall be screened from adjacent residential areas
by fencing or walls. When accessory structures are adjacent to residential
uses, the accessory structure shall not exceed the scale of the adjacent
residential structure(s). Open unenclosed seating, decks or other similar types
of areas are permitted to encroach within the required front setback/yard,
provided that minimum landscape buffer areas are provided per Chapter 10 Part
2.
- Setback from Alley or Rear Property Line The setback
shall be the same as for the required landscape buffer area or transition
setback/yard if applicable, whichever is greater.
- Form District Specific Requirements
- Downtown Form District Accessory structures/screens shall
be designed and constructed of the same materials as the primary structure.
Accessory structures shall only be permitted at the rear of a principal
structure